Type of protection | Performances | Standards |
Re inhaled CO2 (on volunteers) | < 2% | EN 13274-1: 2001 test method part 1 |
Particle penetration | P3/P100 (< 0,03%) | field trials 2 safety valves |
Flame resistant | Conform | 13274-4 methods 3 |
CE marking | BS8468-3.2 | 2009 Type 1 |
Duration of protection against TICs gas and vapor :
- H2S (5000 ppm) > 100 minutes
- Ammoniac (1250 ppm) > 20 minutes
- SO2 (750 ppm) > 30 minutes
- HCN (470 ppm) > 45 minutes
- Phosgene (125 ppm) > 45 minutes
- HD (respiratory and skin) > 30 minutes
- GB (respiratory and skin) >30 minutes